It should be of the maximum available thickness.
Warm roof insulation depth.
There is a requirement when refurbishing a roof to have a minimum u value of 0 18 w m k in england and wales but for a complete re roof in wales the minimum u value required is 0 15 w m k.
Warm roof solutions are generally more.
Ventilation is required for these roofs.
Our u value calculator is free and simple to use for calculating u values specific to your roof construction design.
The typical u value of an existing uninsulated flat roof is 1 5w m2k.
As only a few years ago the recommended depth of insulation was 200mm.
Flat roof insulation thickness.
The below table shows the thickness of insulation required for a typical warm roof construction with insulation fitted above the rafters.
Warm flat roofs do not need to be ventilated as the insulation is.
Cold deck this is where the insulation is placed between the joists rafters or in between the ceiling joists in the case of a pitch roof.
The benefits of a warmer roof 2 3 day installation time.
With a warm roof the usual process is to split the insulation into two layers.
Warm deck the type of insulation for this is usually of a rigid type and the thickness will vary depending on the manufacturer s specifications.
Insulation which prevents any risk of condensation and stops the build up of damp within the roof.
Pipes water tank and loft hatch.
When specifying the insulation for the pitched roof it is important that the thickness of insulation used achieves the required u value.
Insulating between the joists of your loft will keep your house warmer but make the roof space above colder.
Energy efficiency grants are currently available for cold loft roof insulation.
Flat roof insulation always requires professional insulation and damp roofs require professional assessment before work can be carried out.
The chosen insulation laid on top of this should be able to take the weight of anything put above it on the roof without compression or protected from compression by further sheeting.
Our roof conversions can be completed in just 2 3 days.
Cold flat roofs are typically avoided as you d need to install ventilation which can prove problematic for many reasons relating to space labour costs etc.
If 180mm is to be installed then 100mm board might be introduced between the rafters there has to be a minimum 25mm air gap between the insulation and the underside of the tiles or slates with an 80mm board running across the rafters.
To eliminate all condensation risks and making it a true warm roof construction.