Winds can remove roof coverings from the roof sheathing tear roof sheathing from supporting framing see figure 7 4 and rip roof framing from supporting walls.
Steel roof construction details pdf.
Roof pitch the metal roofing panels shown in this manual require a mini mum slope of 2 per foot to ensure proper drainage.
Florida building code allows a minimum pitch of 2 12 for grand rib 3 panels as long as lap screws and sealant are applied to the laps to prevent water from siphoning over the ribs see fig.
Also for exposed fastener panels wall panels tiles soffit fascia copping.
Areas for economy in basic design and house construction are cov ered in numerous.
If a sheet must be bent a gentle 90 degree bend is the maximum recom mended.
4 code the code of standard practice for steel buildings and bridges as published by the american institute of steel construction.
Theses common cross sections and details include more than 100 typical sections that clearly demonstrate how our structural systems integrate with metal tilt up masonry or precast concrete walls.
Metal roofing specifications cad pdf drawings testing bim.
Aluminum and steel roofing and siding sheets are rollformed from hardened tempered metal for maximum strength.
Column a structural element that usually carries its primary loads in compression or tension parallel its axis.
Roof pitch this style of metal roofing panels requires a certain degree of pitch to ensure proper water drainage.
Metal should not be re bent once it has been formed nor should it be folded back on itself.
With any building material or product sound construc tion and installation practices must be followed to assure durability and trouble free performance.
Refer to the rain carrying table in this booklet for the maximum allowable panel length per slope that will provide adequate drainage.
We ve also included common roof and base condition details in pdf and dwg formats.
Cad details document name pdf dwg download all cad construction details 37 1 mb 3 4 mb mc01 identification of roof areas 694 kb 167 kb mc01a single layer underlayment 678 kb 302 kb mc01b double layer underlayment 711 kb 322 kb mc02 vent pipe flashing 626 kb 349 kb mc03 valley.
That structural failures often begin with the roof.
When a metal roofing sheet.
Column base usually a thick plate at the bottom of a column through which anchor bolts mechanically connect the column and transfer forces to the.
For longer slopes and lower roof pitches contact fabral for other suitable profiles.