We have the capabilities to spray and inject a variety of foam systems to achieve a high r value while providing both effective vapor and air barriers.
Spray foam flat roof ventilation.
However in many situations the insulation may need to be primarily or entirely below the flat roof membrane and between the roof joists if so what are the best options.
Since ccspf is a vapour retarder some believe it cannot be used in warm humid climates as it prevents water vapour from going in and out of the assembly.
Froth pak 620 sealant 2 component foam insulation kit a tank b tank 30 hose closed cell quick cure polyurethane expanding spray foam 3 9 out of 5 stars 16 759 00 759.
Closed cell spray foam has a perm rating of approximately 1 5 to 3 0 per 25 mm 1 in and an r value of approximately 1 05 per 25 mm 6 0 per 1 in.
Roof vents are great for allowing air to move and for removing toxic odours from the home.
Of open or closed cell spray foam in their roof or to stack a half foot of rigid foam on the roof deck.
Flat roof spray foam insulation flat roofs with little or no insulation fail to meet the increasingly stringent building regulations of today.
All of these materials are supported by quality assurance testing capabilities that.
Similarly not everyone can afford to spray nearly 10 in.
However many people think that roof vents cannot be used in conjunction with spray foam insulation.
Using closed cell spray foam insulation to fill the cavities and have ventilation throughout the roof will give you roughly an r 31 5.
An alternative option is to insulate the rafter bays with a less expensive insulation like fiberglass or cellulose and to control the temperature of the roof sheathing with rigid foam.
The spray foam solution is a complete vapour barrier which immediately prevents leaks as well as keeping.
Unvented flat roofs a technical discussion flat roofs have often been built with the insulation all on top of the vapor closed drainage plane as this avoids dew point condensation issues inboard of the roofing.
The movement of air into indirect conditioning of an unvented attic is a slow gradual process that will not be noticeable by occupants and typically will not put any strain on the hvac system.
At ifspray we have a spray foam insulation system with special ultimate linings for flat roofs.
However using closed cell spray foam negates the need for ventilation at all and will operate better if you simply do not ventilate the roof and have closed cell spray foam insulation installed.